「Tutorial02」の版間の差分

提供: ComplexRI: Manual
ナビゲーションに移動 検索に移動
 
(3人の利用者による、間の33版が非表示)
1行目: 1行目:
<div><span id="Tutorial02"  style="font-size: 150%;">解析に関する条件を指定しよう</span>➡[[#Explanation of Tutorial02|Explanation of Tutorial02]]</div>
<div><span id="Tutorial02"  style="font-size: 150%;"> Fitting the complex refractive index by manual mode </span> </div>
----
----
:In this tutorial, you practice input the value to the input fields ④ and ⑩.  
: ComplexRI represents the spectra of complex refractive index by
:First, like before, input the value to the fields① and ②. Please, use the same file as the one used in tutorial01 for filed ② .
 
:Then, input the values into the fields ④ and ⑩ like below.
<math> n(\tilde{\nu}) = \eta(\tilde{\nu}) + i \kappa (\tilde{\nu}) = n_j^0 + \sum_{l=1}^{l_{max}} \frac{A_l}{\tilde{\nu}_l - \tilde{\nu} - i \gamma_l} </math>
[[File:02入力ー4.png|frameless|500px]][[File:02入力ー10.png|frameless|500px]]
 
<div id="Explanation of Tutorial02" style="font-size: 150%;">Explanation of Tutorial02</div>
and optimize the set of parameters <math>A_l, \tilde{\nu}_l, \gamma_l</math> and <math>l_{max}</math>. 
Sometimes the fitting procedure is facilitated by giving a set of initial guess.
 
: In this tutorial, we will use the C-C-O asymmetric stretching region of ethanol as an example. The initial parameters in the fitting procedure are set by users.  
: The ATR-IR experimental data file in this tutorial can be downloaded <u><htmltag tagname="a" href="https://comp.chem.tohoku.ac.jp/media/Tutorial/data_ethanol.txt" target="_blank">Here</htmltag></u>. Use Ctrl + s to save the file in your local computer. The file name is “data_ethanol.txt”.  
: Then, please move to the Main Package page.
[[File:Nav-Main.png|1000px]]
: Upload the“data_ethanol.txt” in ① and set the other parameters according to the following figure. (For the meanings of each part, please refer to ➡[[ComplexRI Manual#Manual#Manual|Manual]].)
:[[File:6Newtutorial02.png|1600px]]
: Now, please click the “Execute Fitting” to start fitting.
<div id="Results of Tutorial02" style="font-size: 150%;"> Results of Tutorial02</div>
----
----
:The result should be the like below.
: The Result should be like follows.
[[File:02結果.png|500px]]
[[File:5Newres_tuto02.png|750px]]
:Input fields ④ gives the range of fitting of reflectance spectra. So, the graph is shown in the range you give.
: The meaning of each output can be found in ➡[[ComplexRI Manual#Manual#Manual|Manual]]
:Input fields ⑩ gives the index to finish the fitting. Our fitting continues until the number on top of result become smaller than the value input into the fields⑩.
 
[[Tutorial01|Tutorial01]]

2022年5月26日 (木) 04:50時点における最新版

Fitting the complex refractive index by manual mode

ComplexRI represents the spectra of complex refractive index by

and optimize the set of parameters and . Sometimes the fitting procedure is facilitated by giving a set of initial guess.

In this tutorial, we will use the C-C-O asymmetric stretching region of ethanol as an example. The initial parameters in the fitting procedure are set by users.
The ATR-IR experimental data file in this tutorial can be downloaded Here. Use Ctrl + s to save the file in your local computer. The file name is “data_ethanol.txt”.
Then, please move to the Main Package page.

Nav-Main.png

Upload the“data_ethanol.txt” in ① and set the other parameters according to the following figure. (For the meanings of each part, please refer to ➡Manual.)
6Newtutorial02.png
Now, please click the “Execute Fitting” to start fitting.
Results of Tutorial02

The Result should be like follows.

5Newres tuto02.png

The meaning of each output can be found in ➡Manual

Tutorial01